Humidity Testing Low And Empty Water Level Alarm Temperature Humidity Chamber
Temperature and humidity chamber.pdf
Download:Temperature and humidity chamber.pdf
Standard Features:
2. Specifications :
Range – 40 to 150°C
Temp/Humidity | HD-E702-100-4 | HD-E702-150-4 | HD-E702-225-4 | |
HD-E702-408-4 | HD-E702-800-4 | HD-E702-1000-4 | ||
Temp-only | HD-E702-100T-4 | HD-E702-150T-4 | HD-E702-225T-4 | |
HD-E702-408T-4 | HD-E702-800T-4 | HD-E702-1000T-4 | ||
Temperature Range: | -40°C ~150°C | |||
Cooling Capacity | ~ 2 kW at -20°C | ~ 2.5 kW at -20°C | ~ 4.5 kW at -20°C | |
~ 5.5 kW at-20°C | ~ 8 kW at -20°C | ~ 8.5 kW at - -20°C | ||
Heating System | ~ 5 kW | ~ 5 kW | ~ 5.5 kW | |
~6.5 kW | ~ 8.5 kW | ~ 9 kW | ||
Temperature Fluctuation: | ±0.5°C | |||
Temperature Gradient: | ±0.5°C~±0.2°C | |||
Heating Rate†: | ≥3℃ / min average ( Advance model 5 – 15 ℃ / min) | |||
Cooling Rate†: | ≥1℃ / min average (Advance model 5 - 15℃ / min) | |||
Humidity Range: | 10%~95%RH (Ref to Normal Humidity Range Diagramed) | |||
Humidity Fluctuation: | ±1.5%RH~±2.0%RH | |||
Humidity Gradient: | ±3%RH | |||
Dimensions | ||||
Workspace dimensions | 500x400x500 HD-E702-100 | 600x500x500 HD-E702-150 | 750x500x600 HD-E702-225 | |
850x650x800 HD-E702-800 | 1000x1000x800 HD-E702-800 | 1000x1000x1000 HD-E702-1000 | ||
Exterior dimensions | 1400x850x1050 | 1500x950x1050 | 1650x950x1150 | |
1750x1050x1350 | 1900x1450x1350 | 1900x1450x1550 | ||
Site Requirements | ||||
Electrical Supply: | 208V 3Ø 60Hz or 230V 3Ø 60Hz (customer specific) | |||
Humidity Water | Distilled Water | |||
Condensate Drain: | 1/2" hose connection (gravity drain) |
Range – 70 to 150°C
Temp/Humidity | HD-E702-100-7 | HD-E702-150-7 | HD-E702-225-7 | |
HD-E702-408-7 | HD-E702-800-7 | HD-E702-1000-7 | ||
Temp-only | HD-E702-100T-7 | HD-E702-150T-7 | HD-E702-225T-7 | |
HD-E702-408T-7 | HD-E702-800T-7 | HD-E702-1000T-7 | ||
Temperature Range: | -70°C ~150°C | |||
Cooling Capacity | ~ 2.5 kW at -50°C | ~ 3 kW at -50°C | ~ 5 kW at -50°C | |
~ 6.5 kW at-50°C | ~ 8.5 kW at -50°C | ~ 9 kW at - -50°C | ||
Heating System | ~ 5 kW | ~ 5 kW | ~ 5.5 kW | |
~6.5 kW | ~ 8.5 kW | ~ 9 kW | ||
Temperature Fluctuation: | ±0.5°C | |||
Temperature Gradient: | ±0.5°C~±0.2°C | |||
Heating Rate†: | ≥3℃ / min average ( Advance model 5 – 15 ℃ / min) | |||
Cooling Rate†: | ≥1℃ / min average (Advance model 5 - 15℃ / min) | |||
Humidity Range: | 10%~95%RH (Ref to Normal Humidity Range Diagramed) | |||
Humidity Fluctuation: | ±1.5%RH~±2.0%RH | |||
Humidity Gradient: | ±3%RH | |||
Dimensions | ||||
Workspace dimensions | 500x400x500 HD-E702-100 | 600x500x500 HD-E702-150 | 750x500x600 HD-E702-225 | |
850x650x800 HD-E702-800 | 1000x1000x800 HD-E702-800 | 1000x1000x1000 HD-E702-1000 | ||
Exterior dimensions | 1400x850x1050 | 1500x950x1050 | 1650x950x1150 | |
1750x1050x1350 | 1900x1450x1350 | 1900x1450x1550 | ||
Site Requirements | ||||
Electrical Supply: | 208V 3Ø 60Hz or 230V 3Ø 60Hz (customer specific) | |||
Humidity Water | Distilled water | |||
Condensate Drain: | 1/2" hose connection (gravity drain) |
3. Performance of Stability High Low Temperature and Humidity Test chamebr:
Get a performance evaluation to help provide the suitable chambers to you.
For better assurance of performance for your temperature and humidity cycling application, Haida can provide a guaranteed performance calculation based on your submitted requirements.
Please use these questions as below as a guide to define your test plan. You can then give this information to our lab consultant or email to us, for review by our lab consultant. A recommended model with appropriate refrigeration size will provide to you.
System & Performance Options
(Normal Humidity Range Diagramed)
4. view:
(Advanced refrigeration design is especially compact for HD-Series Chambers)